Notifications
You must be signed in to change notification settings - Fork 36
Driver Index
##Driver Index
Part of the goal of sMAP is to foster a community support open data aquisition of many different devices. This page has a partial list of drivers distributed with sMAP as part of the smap.drivers package.
Unless otherwise specified, arguments without a default value are required.
####XML
Module: smap.drivers.xml.XMLDriver
Communications: XML over file, http, or python loader
Data: whatever is exposed through the XSLT transform
| Parameter | Decription | Default Value |
|---|---|---|
| URI | URI to load: supported schemes are http, https, file, and python | 30 |
| Rate | Polling frequency (seconds) | |
| Xslt | XSLT transformation to apply to document to convert it to sMAP-XML | |
| Timeformat | python strptime string used to parse the time in the document. | %s |
| Timezone | zone code for the data; the timeformat will be parsed as if it is a local timestamp in the zone. | UTC |
XSLT is a way of applying a declarative transformation to XML documents. Sometimes you can use that to very easily convert existing XML data into sMAP feeds. There are a few sample XSLT transformation available in trunk/xslt:
| Stylesheet | Description |
|---|---|
| greenbutton.xsl | Transformation for US GreenButton data packed inside of Atom(http://naesb.org/espi) |
| obvius.xsl | Generic transformation for Obvius Aquisuite XML data |
| ted5000.xsl | Transform for the Ted 5000 which exports all channels |
####Expression Driver
Module: smap.drivers.expr.ExprDriver
|Parameter |Description |Default Value | --------- |:-----------------------------------------------------------------------:| |Expression |An operator expression to compute | |Restreict |An ArdQuery where-clause restricting the set of input streams | |Group |A tagname specifying how streams are groups when passed into operators |
The expression driver is a way to compute ArdQuery operator expressions over new data. This gives you a way to create new “virtual” sMAP streams based on other data. The driver will create streams corresponding to the output of the query
`apply _Expression_ to data before now where _Restrict_ group by _Group_`As new data arrives, it will be pushed through the expression and published as a new sMAP feed. To avoid circularity, it’s a good idea to make Restrict include at least has Path and not has Metadata/Extra/Operator.
####Dent PowerScout 18
Module: smap.drivers.dent.Dent18
Communications: Modbus over TCP
Data: 6 three-phase electric meters
| Parameter | Description | Default Value |
|---|---|---|
| Address | Hostname of device(or Modbus/IP gateway) | |
| Port | Port | 4660 |
| ModbusBase | Device modbus address | 1 |
| Rate | Polling frequency(seconds) | 20 |
####Veris E30 Panel Meter
Module: smap.drivers.veris.VerisDriver
Communications: Modbus over TCP
Data: 42 single-phase power and energy measurements
| Parameter | Description | Default Value |
|---|---|---|
| Address | Hostname of device (or Modbus/IP gateway) | |
| Port | Port | |
| BusID | Device modbus address | 1 |
| Period | Polling frequency(seconds) | 30 |
####Power Standard Lab pQube
Module: smap.drivers.pqube.PQubeModbus
Communications: Modbus/TCP
Data: Three phase energy, power, and quality measurements
| Parameter | Description | Default Value |
|---|---|---|
| Address | Hostname of device (or Modbus/IP gateway) | 502 |
| Port | Port | 1 |
| SlaveAddress | Device modbus address | 7000 |
| BaseRegister | Base register to start reading at | 30 |
| Rate | Polling frequency (seconds) |
####TED 5000
Module: smap.drivers.ted.Ted5000Driver
Communications: HTTP/XML
| Parameter | Description | Default Value |
|---|---|---|
| Address | URL of device data page | |
| Timezone | Local timezone of device | America/Los_Angeles |
| Rate | Polling frequency (seconds) | 60 |
####UC Berkeley ACme X2
Module: smap.drivers.acmex2.acmex2.ACmeX2Driver
Communications: Proprietary UDP
Data: Per-device energy and power data.
| Parameter | Description | Default Value |
|---|---|---|
| Port | Local IPv6 port to listen on | 702 |
####Obvius Aquisuite
Module: `smap.drivers.obvius.Driver
Communications: Proprietary XML
| Parameter | Description | Default Value |
|---|---|---|
| Url | URL to download from. Set to the link returned by the XML download link on the obvius page (e.g. http://10.0.0.1/setup/devicexml.cgi?ADDRESS=58&TYPE=DATA) | |
| Username | HTTP username to authenticate as | |
| Password | HTTP password | |
| Period | Polling frequency (seconds) | 30 |
| ObviusType | Type of device represented by the xml (see below) |
Device maps are stored in smap.drivers.obvius.sensordb. These map the somewhat opaque mappings present in the Aquisuite XML to nicer sMAP names. You can pick one from device type on the Aquisuite Page. Current mappings are:
| ObviousType | Description |
|---|---|
| Power Measurement ION 6200 | |
| Power Measurement ION 7300 | |
| Power Measurement ION 7330 | |
| Shark 100 | |
| Continental Control Systems LLC, WattNode MODBUS | |
| Dent Power Scout A | |
| Veris Full-Data Energy Meter | |
| SquareD | ? |
| GE Enhanced MicroVersaTrip |
####PG&E GreenButton Downloader
Module: smap.drivers.pge + smap.drivers.xslt.XMLDriver
Communication: Web scrape + XML
PG&E makes residential smartmeter data available, but difficult to download through their webpage. You can combine a mechanized download of the xml with an XSLT transform to create a sMAP source from your PG&E data.
| Parameter | Description | Example Value |
|---|---|---|
| Uri | Set to tell XML driver to use the loader | python://smap.drivers.pge.update |
| Xslt | Path to XSLT stylesheet. Included with the sMAP distribution | xslt/greenbutton.xsl |
| Period | Frequency to poll at. PG&E data updates infrequently. | 86400 |
| Username | PG&E Login | |
| Password | PG&E Password | |
| To | Optional; date to start download at | 1/1/2010 |
| From | Optional; date to end download at | 12/31/2012 |
| Type | Optional; type of data feed to use from the result | "gas" or "electric" |
Here's a full example:
[/pge-gas]
type = smap.drivers.xml.XMLDriver
Uri = python://smap.drivers.pge.update
Xslt = ~/smap-data/xslt/greenbutton.xsl
Period = 86400
Username =
Password =
# From = 1/1/2010
# To = 12/31/2012
Type = gas####Weather Underground
Module: smap.drivers.wunderground.WunderGround
Communications: XML
Data: Current conditions for the station.
| Parameter | Description | Default Value |
|---|---|---|
| Address | WUnderground API URL | [http://api.wunderground.com/weatherstation/WXCurrentObXML.asp |
| ID | WUnderground station ID | KCABERKE25 |
| Rate | Polling frequency (seconds) | 60 |
| Period | Polling frequency (seconds) | 30 |
####NOAA Weather Forecasts
Module: smap.drivers.noaaforecast.NOAAForecast
Communications: XML
| Parameter | Description | Default Value |
|---|---|---|
| lat | Latitude fro forecast | |
| lon | Longitude for forecast |
####NWS Weather Forecasts
Module: smap.drivers.forecastTemp.ForecastTempDriver
Communications: XML
| Parameter | Description | Default Value |
|---|---|---|
| Latitude | Latitude for forecast | |
| Longitude | Longitude for forecast | |
| LocationName | Location name |
####Vaisala WXT 520
Module: smap.drivers.vaisala.VaisalaDriver
Communications: SDI-12 (serial) over IP
| Parameter | Description | Default Value |
|---|---|---|
| Address | Hostname of serial/io bridge | |
| Port | port |
####ETCOT
Module: smap.drivers.ercot.ErcotDriver
####PJM
Module: smap.drivers.pjm.PJMDriver
####NYISO
Module: smap.drivers.nyiso.NYIsoDriver
####MISO
Module: smap.drivers.miso.MIsoDriver
####Washington BPA
Module: smap.drivers.washingtonbpa.BPADriver
####ISO NE
Module: smap.drivers.isone.IsoNEDriver
####CA ISO
Module: smap.drivers.caiso.CaIsoDriver
####CA ISO LMP Data
Module: smap.drivers.caiso_price.CaIsoPrice
| Parameter | Description | Default Value |
|---|---|---|
| Location | LMP Node name | OAKLAND_1_N001 |
####HearX Flow Meter
Module: smap.drivers.heatx.HeatX
Communication: Modbus over TCP
Data: Description from the Central Station Steam Co. Cadillac HEATX BTU Meter
| Parameter | Description | Default Value |
|---|---|---|
| Host | Hostname | |
| Rate | Polling rate (seconds) | 20 |
####Omega iSeries Steam Gauge
Module: smap.drivers.iseries.IseriesSteam
Communication: Proprietary TCP
| Parameter | Description | Default Value |
|---|---|---|
| Host | Hostname | |
| Rate | Polling rate (seconds) | 20 |
####Labjack UE9
Module: smap.drivers.labjack.LabjackDriver
Communication: Labjack modbus. Requires updated Labjack firmware.
|Parameter |Description |Default Value | | --------- |:------------------------------------:| | |ConfModule |Python module name with configuration | |
This module is configured through a python module you must write; here is an example (in a file named labjackconf.py:
BIP_5V = 0x08 # from the datasheet def temp_cal(x): # convert an analog reading to celsius return x*55.57-273.15+255.37 CONF = { 'labjack01' : { 'address' : '10.0.0.1', 'rate' : 10, 'channels' : { 'freezer_bat_temp' : { 'register' : 0, # Ain0 'unit' : 'C', 'calibrate' : temp_cal, 'range' : BIP_5V, }, 'freezer_air_temp' : { 'register' : 2, # Ain1 'unit' : 'C', 'calibrate' : lambda x: (x * 100) - 273.15, 'range' : BIP_5V, }, } }####Reading DB **Module**: `smap.drivers.readingdb.Driver` **Data**: Statistics from a [readingdb](https://github.com/stevedh/readingdb) database. |Parameter |Description |Default Value | | -------- |:----------------------:| ------------ | |Port |ReadingDB database port |4242 |